If you’re searching for an industrial-grade textile calender press that’s especially designed and developed for continuous roll to roll applications, look no further than the DM Series roll to roll sublimation calender press. DM Series roll to roll sublimation calender press is the perfect fit for companies only working with roll fabrics.
With the Diferro DM Series, you’re not just investing in a calender press; you’re investing in the future of your textile production. This industrial workhorse is engineered to provide consistent, high-quality results on a grand scale. It’s the go-to choice for textile printing shops with mass production needs.
Join the ranks of industry leaders who trust Diferro for their large-scale textile printing requirements. Explore the DM Series roll to roll sublimation ccalender press and discover the power of precision, able to work flawlessly for large scale textile manufacturers, with a minimum speed of 300 linear meters/hour. Elevate your textile printing to new heights with Diferro’s DM Series roll to roll sublimation calender press – where speed and power converge.
The cylinder of the DM Series roll to roll calender press is made of high-quality ST44 draw steel pipe material and has a ground surface. Optionally, the cylinder surface can be coated with chrome or Teflon to make it more durable and long-lasting. The cylinder contains a heating unit consisting of three parts, and the drum is filled with transfer oil, which balances the internal pressure of the cylinder. The temperature sensor placed on the surface of the cylinder provides more accurate temperature measurements and results in better printing outcomes. The maximum operating temperature and temperature limitations can be easily adjusted via the touch screen panel. As a result, this cylinder is a high-quality product made of premium materials and advanced features. The fail-safe key mechanism, temperature sensor, and touch screen panel provide easy and safe operation.
All of our machines use 100% Nomex felt reinforced with Kevlar material, specifically designed for industrial use. These felts are non-stretchable and have a long lifespan, typically lasting between 1 to 3 years depending on usage. The machines are equipped with an automatic felt centering system to prevent any shifting of the felt to the left or right. This system operates pneumatically and is supported by an air compressor. In the event of a loss of air pressure, the machine will automatically slow down to protect the felt and allow it to advance and retract for cooling. This system is highly effective in tensioning and centering the felt, and eliminates the need for operators to constantly adjust the felt. It also saves time and improves efficiency in operation. Business owners can rest assured that the felt maintenance is taken care of with this automatic system.
Protection Paper
Digital Paper
Roll Fabric
Piece of Fabric
DM Series comes in various different size options depending on your needs as follows;
400mm Drum Size
600mm Drum Size
1000mm Drum Size
Feature Name | DM-19B400C | DM-22B400C | DM-26B400C | DM-33B400C |
Supply Voltage | 380…415 VACor 220 VAC – 3 Ph 50/60 | 380…415 VACor 220 VAC – 3 Ph 50/60 | 380…415 VACor 220 VAC – 3 Ph 50/60 | 380…415 VACor 220 VAC – 3 Ph 50/60 |
Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
Number of Phases | ~3 PH | ~3 PH | ~3 PH | ~3 PH |
Electrical Connection Type | ~3PH + N + PE€ | ~3PH + N + PE€ | ~3PH + N + PE€ | ~3PH + N + PE€ |
Total power | 33 kW | 40 kW | 55 kW | 62 kW |
Total Current | 50 A | 61 A | 84 A | 94.5 A |
Resistance Power | 31.5 kW | 38.5 kW | 53 kW | 60 kW |
Resistance Current | 48 A | 58.5 A | 80.5 A | 91 A |
Electrical Main Line Supply Cable Cross Section | 4 × 10 + 6 mm² | 4 × 10 + 6 mm² | 4 × 16 + 6 mm² | 4 × 25 + 16 mm² |
Heating system | Heat Transfer Oil | Heat Transfer Oil | Heat Transfer Oil | Heat Transfer Oil |
Max. Heat | 230 °C | 230 °C | 230 °C | 230 °C |
Average Warm Up Time | 90 min | 90 min | 90 min | 90 min |
Average Cooling Time | 180 – 300 min | 180 – 300 min | 180 – 300 min | 180 – 300 min |
Air pressure | 5 – 8 BAR | 5 – 8 BAR | 5 – 8 BAR | 5 – 8 BAR |
Electrical System | PLC Control | PLC Control | PLC Control | PLC Control |
Felt Tension System | Pneumatic | Pneumatic | Pneumatic | Pneumatic |
Felt Direction Control | Automatic with Limit Switch and Pneumatic Piston | Automatic with Limit Switch and Pneumatic Piston | Automatic with Limit Switch and Pneumatic Piston | Automatic with Limit Switch and Pneumatic Piston |
Speed Control | AC Inverter | AC Inverter | AC Inverter | AC Inverter |
Weekly Programming | There is | There is | There is | There is |
Automatic Cooling | There is | There is | There is | There is |
Automatic Shutdown After Cooling | There is | There is | There is | There is |
Safety | 4 Emergency Stop Buttons, Safety Rope | 4 Emergency Stop Buttons, Safety Rope | 4 Emergency Stop Buttons, Safety Rope | 4 Emergency Stop Buttons, Safety Rope |
Touchscreen Interface Language | Turkish English | Turkish English | Turkish English | Turkish English |
Warranty Period | 1 year | 1 year | 1 year | 1 year |
UPS Connection Input | Yes (L – N 200…240VAC 10A) | Yes (L – N 200…240VAC 10A) | Yes (L – N 200…240VAC 10A) | Yes (L – N 200…240VAC 10A) |
Cylinder Diameter (mm) | 400mm | 400mm | 400mm | 400mm |
Cylinder Diameter (Inch) | 15.80″ | 15.80″ | 15.80″ | 15.80″ |
Cylinder Width (mm) | 1900mm | 2200mm | 2600mm | 3300mm |
Cylinder Width (Inch) | 74.80″ | 85.60″ | 102.30″ | 129.90″ |
Working Width (mm) | 1800mm | 2100mm | 2500mm | 3200mm |
Working Width (Inch) | 70.90″ | 82.70″ | 98.40″ | 126.00″ |
Feature Name |
DM-19B600C |
DM-22B600C |
DM-26B600C |
DM-33B600C |
Supply Voltage | 380…415 VACor 220 VAC – 3 Ph 50/60 | 380…415 VACor 220 VAC – 3 Ph 50/60 | 380…415 VACor 220 VAC – 3 Ph 50/60 | 380…415 VACor 220 VAC – 3 Ph 50/60 |
Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
Number of Phases | ~3 PH | ~3 PH | ~3 PH | ~3 PH |
Electrical Connection Type | ~3PH + N + PE€ | ~3PH + N + PE€ | ~3PH + N + PE€ | ~3PH + N + PE€ |
Total power | 43 kW | 45 kW | 56 kW | 86 kW |
Total Current | 65.5 A | 68.5 A | 85 A | 131 A |
Resistance Power | 41.5 kW | 43 kW | 53 kW | 83 kW |
Resistance Current | 63 A | 65.5 A | 80.5 A | 126 A |
Electrical Main Line Supply Cable Cross Section | 4 × 16 + 10 mm² | 4 × 16 + 10 mm² | 4 × 25 + 16 mm² | 4 × 35 + 16 mm² |
Heating system | Heat Transfer Oil | Heat Transfer Oil | Heat Transfer Oil | Heat Transfer Oil |
Max. Heat | 230 °C | 230 °C | 230 °C | 230 °C |
Average Warm Up Time | 90 min | 90 min | 90 min | 90 min |
Average Cooling Time | 180 – 300 min | 180 – 300 min | 180 – 300 min | 180 – 300 min |
Air pressure | 5 – 8 BAR | 5 – 8 BAR | 5 – 8 BAR | 5 – 8 BAR |
Electrical System | PLC Control | PLC Control | PLC Control | PLC Control |
Felt Tension System | Pneumatic | Pneumatic | Pneumatic | Pneumatic |
Felt Direction Control | Automatic with Limit Switch and Pneumatic Piston | Automatic with Limit Switch and Pneumatic Piston | Automatic with Limit Switch and Pneumatic Piston | Automatic with Limit Switch and Pneumatic Piston |
Speed Control | AC Inverter | AC Inverter | AC Inverter | AC Inverter |
Weekly Programming | There is | There is | There is | There is |
Automatic Cooling | There is | There is | There is | There is |
Automatic Shutdown After Cooling | There is | There is | There is | There is |
Safety | 4 Emergency Stop Buttons, Safety Rope | 4 Emergency Stop Buttons, Safety Rope | 4 Emergency Stop Buttons, Safety Rope | 4 Emergency Stop Buttons, Safety Rope |
Touchscreen Interface Language | Turkish English | Turkish English | Turkish English | Turkish English |
Warranty Period | 1 year | 1 year | 1 year | 1 year |
UPS Connection Input | Yes (L – N 200…240VAC 10A) | Yes (L – N 200…240VAC 10A) | Yes (L – N 200…240VAC 10A) | Yes (L – N 200…240VAC 10A) |
Cylinder Diameter (mm) | 600mm | 600mm | 600mm | 600mm |
Cylinder Diameter (Inch) | 23.60″ | 23.60″ | 23.60″ | 23.60″ |
Cylinder Width (mm) | 1900mm | 2200mm | 2600mm | 3300mm |
Cylinder Width (Inch) | 74.80″ | 85.60″ | 102.30″ | 129.90″ |
Working Width (mm) | 1800mm | 2100mm | 2500mm | 3200mm |
Working Width (Inch) | 70.90″ | 82.70″ | 98.40″ | 126.00″ |
Feature Name |
DM-19B1000C |
DM-22B1000C |
DM-26B1000C |
DM-33B1000C |
Supply Voltage | 380…415 VACor 220 VAC – 3 Ph 50/60 | 380…415 VACor 220 VAC – 3 Ph 50/60 | 380…415 VACor 220 VAC – 3 Ph 50/60 | 380…415 VACor 220 VAC – 3 Ph 50/60 |
Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
Number of Phases | ~3 PH | ~3 PH | ~3 PH | ~3 PH |
Electrical Connection Type | ~3PH + N + PE€ | ~3PH + N + PE€ | ~3PH + N + PE€ | ~3PH + N + PE€ |
Total power | 71 kW | 78 kW | 93 kW | 120 kW |
Total Current | 108 A | 118.5 A | 141.5 A | 182.5 A |
Resistance Power | 68 kW | 75 kW | 90 kW | 116 kW |
Resistance Current | 103.5 A | 114 A | 137 A | 176.5 A |
Electrical Main Line Supply Cable Cross Section | 4 × 35 + 16 mm² | 4 × 35 + 16 mm² | 4 × 50 × 25 mm² | 4×70×50mm² |
Heating system | Heat Transfer Oil | Heat Transfer Oil | Heat Transfer Oil | Heat Transfer Oil |
Max. Heat | 230 °C | 230 °C | 230 °C | 230 °C |
Average Warm Up Time | 90 min | 90 min | 90 min | 90 min |
Average Cooling Time | 180 – 300 min | 180 – 300 min | 180 – 300 min | 180 – 300 min |
Air pressure | 5 – 8 BAR | 5 – 8 BAR | 5 – 8 BAR | 5 – 8 BAR |
Electrical System | PLC Control | PLC Control | PLC Control | PLC Control |
Felt Tension System | Pneumatic | Pneumatic | Pneumatic | Pneumatic |
Felt Direction Control | Automatic with Limit Switch and Pneumatic Piston | Automatic with Limit Switch and Pneumatic Piston | Automatic with Limit Switch and Pneumatic Piston | Automatic with Limit Switch and Pneumatic Piston |
Speed Control | AC Inverter | AC Inverter | AC Inverter | AC Inverter |
Weekly Programming | There is | There is | There is | There is |
Automatic Cooling | There is | There is | There is | There is |
Automatic Shutdown After Cooling | There is | There is | There is | There is |
Safety | 4 Emergency Stop Buttons, Safety Rope | 4 Emergency Stop Buttons, Safety Rope | 4 Emergency Stop Buttons, Safety Rope | 4 Emergency Stop Buttons, Safety Rope |
Touchscreen Interface Language | Turkish English | Turkish English | Turkish English | Turkish English |
Warranty Period | 1 year | 1 year | 1 year | 1 year |
UPS Connection Input | Yes (L – N 200…240VAC 10A) | Yes (L – N 200…240VAC 10A) | Yes (L – N 200…240VAC 10A) | Yes (L – N 200…240VAC 10A) |
Cylinder Diameter (mm) | 1000mm | 1000mm | 1000mm | 1000mm |
Cylinder Diameter (Inch) | 39.40″ | 39.40″ | 39.40″ | 39.40″ |
Cylinder Width (mm) | 1900mm | 2200mm | 2600mm | 3300mm |
Cylinder Width (Inch) | 74.80″ | 85.60″ | 102.30″ | 129.90″ |
Working Width (mm) | 1800mm | 2100mm | 2500mm | 3200mm |
Working Width (Inch) | 70.90″ | 82.70″ | 98.40″ | 126.00″ |
Enables the operator to control the tension the input fabric by a rod installed in the middle of the machine.
Able to inflate and deflate mechanism provides an almost perfect grip on the rollers placed on it. One of the most important features of the air shaft is to protect the sensitivity of the material on the rollers. Thus, it aims to increase production speed and maximize production efficiency.
The antistatic bar eliminates static electricity generated during transfer, preventing harm to users. Static electric generated during the transfer of sensitive materials can damage the material and cause disruptions in the production process.
The antistatic bar solves this problem, making the production process more efficient and safe. Additionally, the use of an antistatic bar helps with the easy and smooth transfer of materials. This increases production speed and makes the quality control process easier.
A cylinder scraper is a mechanism that is commonly used in production lines. It is designed to clean unwanted substances such as dirt, dust, and other residues that accumulate and stick to the surface of the cylinder.
The scraper has a blade that comes into contact with the surface of the cylinder and cleans the residues that accumulate during the rotation of the cylinder. This helps prevent residues from damaging products or other machines.
In addition, the cylinder scraper also helps increase the efficiency of production lines. Residues and dirt that stick to the cylinder surface can slow down the speed of the production line or damage machines. With the cylinder scraper, these problems can be prevented and the production process can be made more efficient.
Apparatus for cooling the hot fabric coming out of the machine.
Is a card module installed on the PLC. Provides control over the machine even when you are not around. Enables Diferro to connect to themachine for troubleshooting.
Eliminates the fume generated during the sublimation process and ensures that the fumes don’t spread around. Good choice to prevent the fume affect the operator.
This unit helps guiding the fabric and and centering it in case if it is misfed to the machine and prevents the print output to be damaged.
Helps to lay down the printed fabrics to the desired place. This unit is also helpful for a better cooling of the fabric, as the fabric travels more distance.
It is for the winding of the output fabric roll not on the machine but on the unit, so that the printed fabric can be better cooled off, thus providing more space to work easily.
It is for those who wish to continue with spare digital paper roll without stopping the machine, so that the printing can continue without interruption.
This unit automatically cuts the edges of the fabric, providing a sharper and more defined edge.
This unit is for the fabrics need crushing. Generally used for laminating.
Feeds the paper and the fabric below the platform so that the operator has the space in front of the machine to be able to work and walk.
This option is for those who want to to lamination as well. Used for the special fabrics who needs crushing.
It prevents damage from heat by continuously turning the spindle when the machine energy is cut off. From the moment the energy is cut off, it keeps the machine running continuously for 3-5 hours and allows the machine to cool down.